VSS2562

Massive Capacity, High Availability and High-Performance 2U 56-Bay NVMe Storage Server

The Viking Enterprise Solutions (VES) VSS2562 is a cutting-edge high availability storage server that delivers unparalleled storage capacity, performance, and efficiency. Designed to meet the demands of modern data-intensive workloads, this server boasts a dense configuration of fifty-six (56), 2.5” NVMe drives, leveraging PCIe 4.0 technology to deliver blazing-fast data transfer speeds and minimal latency.

VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
previous arrow
next arrow
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
VSS2562
previous arrow
next arrow

The VES patented VSS2562 is a dense, high-availability storage solution that provides up to 3.3 PB’s in a 2U form factor using 60 TB drives.

The enclosure contains two hot swappable server modules. Each of the server modules is a single socket AMD Milan-based server with two x16 PCIe add in card slots, and up to 8 DIMMs per CPU. The VSS2562 fits into an industry standard 19” wide by 1m deep rack. Its flexible configuration allows it to be deployed in a variety of applications.

Key Features

  • Accommodates up to 56 NVMe drives in a 2U chassis, providing enormous storage capacity for data-intensive applications.
  • Leverages the latest NVMe technology to deliver lightning-fast data transfer speeds and minimal latency.
  • Optimized 2U form factor maximizes space utilization in data centers.
  • Incorporates redundant power supplies, hot-swappable components, and high availability options to ensure continuous operations.
  • Supports flexible configuration options to adapt to changing storage requirements.
  • PCIe Gen4 NVMe support for 20 SSD slots
  • SFF-8639, PCIe Gen “3/4” NVMe (U.2) drive support (up to 18W per drive)
  • Single and dual port NVMe drive support. Single port drives are only seen by one server
  • Resilient environmental specification with up to a 35C ambient inlet
  • Standard chassis customization & branding available

Use Cases

Database Management Systems: Handling large datasets and complex queries efficiently.
Virtualization and Cloud Computing: Supporting multiple virtual machines and applications with low latency.
Big Data Analytics: Processing and analyzing massive datasets in real-time.
AI and Machine Learning: Training and deploying complex models.
Video Surveillance and Analytics: Storing and processing high-resolution video feeds.

Target Market

Financial Services: High-frequency trading, risk management, data analytics, and real-time transaction processing.
Cloud Service Providers: Delivering cloud-based services, storage-as-a-service, and infrastructure-as-a-service.
Enterprise IT: Data centers, large-scale databases, virtualization, and business intelligence.
Media and Entertainment: Video editing, rendering, animation, and content delivery networks (CDNs).
Healthcare: Medical imaging, genomics, and electronic health records.
High-Performance Computing (HPC): Scientific simulations, data analysis, and machine learning.

Benefits

Unmatched storage density: Store massive amounts of data in a minimal footprint.
Accelerated application performance: Improve application responsiveness with PCIe 4.0 speeds.
Optimized data center efficiency: Maximize space utilization and reduce power consumption.
Enhanced business agility: Quickly adapt to changing data storage needs.
Reduced operational costs: Improve storage efficiency and lower management overhead.

Competitive Advantage

The VES VSS2562 stands out from the competition by offering an unparalleled combination of massive capacity and high performance in a compact 2U form factor. Its ability to handle demanding workloads while optimizing space and power consumption makes it an ideal solution for organizations seeking to maximize their storage infrastructure.

AC Power Hot-Swappable Components Firmware 2U Enclosure
  • Input voltage: 200-240VAC
  • Input frequency: 50-60 Hz
  • Power source: redundant 2.7kwatt power supplies
  • Input current: 15 amps max @ 180V AC per power supply
  • Inrush current: 40 amps peak per power supply
  • Maximum system continuous DC output power rating: 2.7kwatts
  • Two Server Modules
  • Eight server fans
  • Four SSD fans
  • Two AC to DC power supplies − Each supply provides up to 2700W of power
  • Two independent AC power inputs
  • 56 NVMe drives (hot pluggable)

 

 

 

  • IPMI and Redfish 1.16 management
  • CLI and GUI control for drive management & status of the enclosure

 

 

 

 

 

  • Dimensions: 3.2 in. H X 17.6 in. W X 34.42 in. D (81 mm H X 448 mm W X 874 mm D)
  • Weight with drives: 85 lbs (39 kg) max
  • Railkit with CMA Failure Notifications

 

 

 

 

Failure Notifications Operating Environment Non-Operating Environment Drive Partitioning
  • Status & fault LEDs for the enclosure, drives & servers
  • Performance
  • Up to 128 GB/s bandwidth between both servers
  • Capacity
  • 56-drive capacity
    • U.2 PCIe 4.0 NVMe drives
    • Dual port drive
    • Up to 18W per drive
  • Temperature: 5° to 35°C
  • Relative humidity: 20% to 80% (non-condensing)
  • Altitude: -200 to 10,000 ft
  • Shock: 3G at 11ms, 1/2 sine wave pulse
  • Vibration: 0.10G at 5 Hz to 500 Hz

 

 

 

  • Temperature: -40° to 60°C
  • Relative humidity: 10% to 90% (non-condensing)
  • Altitude: -200 to 40,000 ft
  • Shock: 10G at 11ms, 1/2 sine wave pulse
  • Vibration: 0.5G at 5 Hz to 500 Hz

 

 

 

  • Management software controls the visibility & access to each drive
  • One port of a single port drive can be hidden for data protection

 

 

 

 

 

Safety Standards Servers Electromagnetic Emissions & Immunity Standards Monitoring & Reporting
  • IEC 62368-1:3rd Ed, 2021-10-22
  • CAN/CSA C22.2 No. 62368-1:19, 3rd Ed, 2021-10-22
  • Quality Standards
  • Manufactured under an ISO 9002 registered quality system

 

 

 

 

 

 

  • One or two Server modules
  • AMD Milan processors
    • In High Performance configuration
      Each server takes 2x x16 PCIe v4 add in card

OR

  • In High Availability configuration
    Each server takes 1x OCP v3 and 1x HHHL PCIe Gen4 add in card

 

 

 

  • EN 55032:2015 + A11:2020
  • EN 55035:2017 + A11:2020
  • EN 61000-3-2:2014
  • EN 61000-3-3:2013 +A1:2019
  • FCC 47 CFR PART 15 CLASS A SUBPART B
  • CANADIAN ICES-003 ISSUE 7:2020
  • CANADIAN ICES-Gen Issue 1 +A1:2021
  • VCCI-CISPR 32:2016
  • CE Mark

 

 

 

  • Monitors temperature, power, cooling (including fan speed control), drives, as well as error rates & quality of service
  • Reporting of all serial number, part number, & revisions of the server modules, power supplies, drives & chassis

 

 

 

 

 

 

 

VSS2562

VSS2562: A high density NVME storage server that offers fifty-six, 2.5” PCIe NVMe drives (U.2) combined with two server modules.